Full Synthetic Air Compressor Oil VDL 32#/46#/68#
Product Description
Specifications and Approvals
- • DIN 51506: VDL
- • ISO 6743-3: DAJ
Performance Benefits
-
• Long oil lifeSave maintenance costs: oil change interval can reach 3000 hours even under the maximum exhaust temperature of 100℃ operating conditions.
-
• Excellent wear protectionExcellent anti-wear protection properties effectively ensure protection of the internal metal surface of the compressor and reduce corrosion and wear.
-
• Protect system efficiencyExcellent air release and anti-foam properties ensure reliable start and stability of continuously compressed gas. Air compressor oil VDL allows rapid air release without excessive foam.
Applications
Full Synthetic Air Compressor Oil VDL 32#/46#/68# is recommended for rotary sliding vane air compressor.
Typical Test Data
Full Synthetic Air Compressor Oil VDL 32#
Test Item | Result | Method |
Density (20℃), g/cm³ | 0.83 | ASTM D4052 |
Kinematic Viscosity (40℃), mm²/s | 32.1 | ASTM D445 |
Kinematic Viscosity (100℃), mm²/s | 5.91 | ASTM D445 |
Viscosity Index | 130 | ASTM D2270 |
Pour Point, ℃ | -48 | ASTM D97 |
Flash Point (COC), ℃ | 230 | ASTM D92 |
Water Separability, minutes | 10 | ASTM D1401 |
Full Synthetic Air Compressor Oil VDL 46#
Test Item | Result | Method |
Density (20℃), g/cm³ | 0.84 | ASTM D4052 |
Kinematic Viscosity (40℃), mm²/s | 45.1 | ASTM D445 |
Kinematic Viscosity (100℃), mm²/s | 7.61 | ASTM D445 |
Viscosity Index | 136 | ASTM D2270 |
Pour Point, ℃ | -48 | ASTM D97 |
Flash Point (COC), ℃ | 240 | ASTM D92 |
Water Separability, minutes | 10 | ASTM D1401 |
Full Synthetic Air Compressor Oil VDL 68#
Test Item | Result | Method |
Density (20℃), g/cm³ | 0.848 | ASTM D4052 |
Kinematic Viscosity (40℃), mm²/s | 67.3 | ASTM D445 |
Kinematic Viscosity (100℃), mm²/s | 10.12 | ASTM D445 |
Viscosity Index | 135 | ASTM D2270 |
Pour Point, ℃ | -48 | ASTM D97 |
Flash Point (COC), ℃ | 248 | ASTM D92 |
Water Separability, minutes | 10 | ASTM D1401 |
Health, Safety & Environment
Avoid contact with skin. Use impervious gloves with used oil. After skin contact, wash immediately with soap and water.
Take used oil to an authorised collection point. Do not discharge into drains, soil or water.