Please Enter Your Search Text.
Search text
YUANGEN YUANGEN
Inquiry
Submission successful

Turbine Oil L-TSA 32#/46#/68#

Product Description

Turbine Oil L-TSA 32#/46#/68# is formulated with high-quality hydrotreated base oil and ashless additives, providing excellent oxidation stability, outstanding rust and corrosion protection, low foaming tendency, and superior demulsibility. It meets the specific anti-wear requirements of steam turbines and light-duty gas turbines without gearboxes.
• Packaging: 18L, 200L
• Customized packaging available upon request.
Turbine Oil L-TSA 32#/46#/68#
Turbine Oil L-TSA 32#/46#/68#

Specifications and Approvals

  • • AGMA 9005-F16 R&O
  • • ASTM D-4304 TYPE I, II, III
  • • BRITISH STANDARD BS 489
  • • DIN 51506 VDL
  • • Fives Cincinnati P-38
  • • GEK 101941A, 32568K, 121608, 27070
  • • GEK 46506E, 28143 B Type I
  • • INDIAN STANDARD IS 1012
  • • ISO 8068 TSA and TGA
  • • ISO 8068 TGE TSE
  • • JIS K2213 TYPE 2
  • • SIEMENS FLUID SPECIFICATION 65/0027
  • • SIEMENS AG TLV 9013 04 STANDARD THERMAL STABILITY
  • • SIEMENS AG TLV 9013 05 HIGH THERMAL STABILITY
  • • Solar Turbines ES 9-224

Performance Benefits

  • • Superior Oxidation Resistance
    Formulated with high-quality hydrotreated base oil and ashless high-performance additives, it effectively extends service life, reduces the formation of corrosive acids and sludge, and lowers operating costs.
  • • Excellent Foam Resistance and Air Release Ability
    with outstanding foam resistance and rapid air release, it significantly reduces pump cavitation, excessive wear, and premature oil oxidation, thereby enhancing system reliability.
  • • Outstanding Water Separation Performance
    Excess water in steam turbines can be quickly drained, minimizing component corrosion and early wear while significantly reducing the risk of unplanned maintenance.
  • • Exceptional Rust and Corrosion Protection
    Even in humid or water-contaminated environments, the oil prevents rust and corrosion during operation or extended shutdowns, ensuring optimal component protection and minimizing maintenance costs

Applications

Turbine Oil L-TSA 32#/46#/68# is ideal for industrial steam turbines and light-duty gas turbines that do not require enhanced anti-wear performance for gearboxes. It is also suitable for the lubrication of hydraulic turbines and can be used in light-duty gas turbines, industrial drives, marine propulsion systems, and control systems for both lubrication and sealing.


Get detailed product specifications and have our technical experts confirm whether this formulation is suitable for your equipment.
ACCESS PRODUCT DATA

Typical Test Data

Turbine Oil L-TSA 32#


Test Item

Result

Method

Density (20), g/cm³

0.855

ASTM D4052

Colour Scale

L0.5

ASTM D1500

Kinematic Viscosity (40),   mm²/s

32.1

ASTM D445

Kinematic Viscosity (100),   mm²/s

 

5.4

ASTM D445

Viscosity Index

102

ASTM D2270

Pour Point,

 

-33

ASTM D97

Flash Point (COC),

234

ASTM D92

Water Separability, minutes

10

ASTM D1401

The oxidation stability test (TOST) life, hours

10000+

ASTM D943


Turbine Oil L-TSA 46#


Test Item

Result

Method

Density (20), g/cm³

0.865

ASTM D4052

Colour Scale

L0.5

ASTM D1500

Kinematic Viscosity (40),   mm²/s

 

46.2

ASTM D445

Kinematic Viscosity (100),   mm²/s

7.0

ASTM D445

Viscosity Index

109

ASTM D2270

Pour Point,

-30

ASTM D97

Flash Point (COC),

242

ASTM D92

Water Separability, minutes

10

ASTM D1401

The oxidation stability test (TOST) life, hours

 

10000+

ASTM D943


Turbine Oil L-TSA 68#


Test Item

Result

Method

Density (20), g/cm³

0.875

ASTM D4052

Colour Scale

L0.5

ASTM D1500

Kinematic Viscosity (40),   mm²/s

68.2

ASTM D445

Kinematic Viscosity (100),   mm²/s

8.9

ASTM D445

Viscosity Index

104

ASTM D2270

Pour Point,

-24

ASTM D97

Flash Point (COC),

248

ASTM D92

Water Separability, minutes

10

ASTM D1401

The oxidation stability test (TOST) life, hours

7000+

ASTM D943


Health, Safety & Environment

The product is unlikely to present any significant health or safety hazard when properly used in the recommended application, and good standards of personal hygiene are maintained.
Avoid contact with skin. Use impervious gloves with used oil. After skin contact, wash immediately with soap and water.
Take used oil to an authorised collection point. Do not discharge into drains, soil or water.

Storage

All packages should be stored under cover. Where outside storage is unavoidable, drums should be laid horizontally to avoid the possible ingress of water and damage to drum markings. Products should not be stored above 60°C, exposed to direct sunlight or freezing conditions.
The indicated properties are typical of those obtained with normal production tolerance and do not constitute a specification. All the information contained in this document is considered accurate as of date of printing, and no warranty or representation, expressed or implied is made as to the accuracy of the data and information in this publication. The information contained herein is subject to change without notice.
Access Product Data and Verify Equipment Compatibility
For data security, YUANGEN does not disclose detailed product information on this website. Please briefly describe your equipment and application, and our technical team will review your request, provide accurate product specifications, and offer guidance on equipment compatibility.
  • First Name
  • Last Name
  • Company Name
  • Country
  • Email
  • Phone / WhatsApp
  • Description
YUANGEN undertakes to protect your personal information. All information provided
will be processed exclusively for business communication purposes.
SUBMIT
Partner with Yuangen
Reliable Lubrication Solutions for Heavy Industry
Submit your request, and our team will respond within 12 hours.
  • Name
  • Company Name
  • Country
  • Email
  • Phone / WhatsApp
  • Description
YUANGEN undertakes to protect your personal information. All information provided will be processed exclusively for business communication purposes.
SUBMIT INQUIRY